MEDICAL USB GALVANIC ISOLATOR

Inquiry

The patient treatment area dimensions are defined as a radius of 1.5 m around the treatment area. The treatment area must use the equipment approved according to EN60601. Often however, non-medical approved equipment is attached to the medical devices.
IEC 60601 approved medical PC is electrically safe, but the connected office printer or other equipment poses a risk to patient safety. If the device has a short circuit or causes voltage spikes, these can pass through the interface cable (USB) along the medical computer and through it directly to the medical device. If the medical device is connected to the patient, then the patient suffers an electric shock.
In order to avoid all possible risks, use isolator with 2MOPP safety certification to accomplish the patient treatment area is very important, providing protection and security for human, device and PC.
No drivers needed. Automatic detection and switch of the transfer rate: Low Speed (1.5MBits/s) and Full Speed (12MBits/s). Optional power supplies is recommended for end devices which draw more than 250mA.

Specification UIBA000
DC Isolation 6,000V 1min
Supply Isolated Current
USB +5V @ 250 mA (Max)
Ambient Conditions During Operation Temperature: 0°C to +40°C
Relative humidity: 10% to 90% (non-condensing)
Ambient Conditions During Transport / Storage Temperature: -25°C to +85°C
Relative humidity: 10% to 95% (non-condensing)
Specification of The Data Connections
USB 1.1 Low-Speed (1.5Mbps), USB 2.0 Full-Speed (12Mbps)
Behaves USB-compliant as a self-powered USB hub
Insulation 2MOPP
Connections USB-A, USB-B, Power supply connector (DC JACK)
Protection Against Harmful Intrusion of Water or Solid Substances IP30
Dimension Housing 55mm x 89mm x 24mm
Certifications

Safety IEC 60601-1, EMC IEC 60601-1-2
CE, FCC Part18, CAN/CSA-C22.2 No. 60601-1
UL and C-UL based on ANSI/AAMI ES 60601-1

Specification UIBA000
Power Adaptor (Optional) 80-275V AC
Output Range 5.99V DC/ 2A Max.
Continuous Output Power 12W max in ambient temperature under -10°C to +40°C
Ambient Conditions During Operation Temperature: -10°C to +40°C
Relative humidity: 10% to 95% (non-condensing)
Insulation From input line to output should be 4000V AC for 60 seconds
Connections Input connector: AC plug (EU or UL type)
Output connector: Barrel Female Plug
Safety Certifications UL and C-UL based on ANSI/AAMI ES 60601-1
CAN/CSA-C22.2 No. 60601-1, IEC 60601-1

TUV T-Mark based on EN 60601-1
  • The USB isolator provides separation 2MOPP
  • insulation between the master port and the slave port.
  • REINFORCED INSULATION of 6000 V DC for 1 minute.
  • Certified to the latest UL/IEC 60601-1 & 60601-1-2 standard
  • FCC Part 18 certified
  • USB 2.0 (12Mbit/s) full-speed supported with overload proof
  • Works out of the box, no drivers needed.
  • Lightweight and optional mounting bracket for Din rail mounting
  • Works also with hubs and extenders
  • For all medical and industrial applications
Oneline Help